Dies ist eine Übersichtsseite mit Metadaten zu dieser wissenschaftlichen Arbeit. Der vollständige Artikel ist beim Verlag verfügbar.
Evaluation of Tumor Angiogenesis of Breast Carcinoma Using Contrast-Enhanced Digital Mammography
175
Zitationen
7
Autoren
2006
Jahr
Abstract
OBJECTIVE: The purpose of this article is to assess the accuracy of contrast-enhanced digital mammography in the detection of breast carcinoma and to correlate the findings on the images with those of histologic analysis using microvessel quantification. SUBJECTS AND METHODS: Twenty patients with a suspicious breast abnormality underwent contrast-enhanced digital mammography using a full-field digital mammography unit that was modified to detect iodinated enhancement. For each patient, a total of six contrast-enhanced craniocaudal views were acquired from 30 seconds to 7 minutes after the injection of a bolus of 100 mL of an iodinated contrast agent. Image processing included a logarithmic subtraction and the analysis of enhancement kinetic curves. Contrast-enhanced digital mammography findings were compared with histologic analysis of surgical specimens, including intratumoral microvessel density quantification evaluated on CD34-immunostained histologic sections obtained from all patients. RESULTS: An area of enhancement was depicted on contrast-enhanced digital mammograms in 16 of the 20 histologically proven breast carcinomas. Excellent correlation was seen between the size of enhancement and the histologic size of tumors, which ranged from 9 to 22 mm. Early enhancement with washout was observed in four cases, early enhancement followed by a plateau in four cases, gradual enhancement in seven cases, and unexpected decrease of enhancement in one case. Intratumoral microvessel density ranged from 11.7 to 216.6 microvessels per square millimeter. A poor correlation was found between data measured on contrast-enhanced digital mammography and intratumoral microvessel density measured on CD34-immunostained histologic sections. CONCLUSION: Contrast-enhanced digital mammography is able to depict angiogenesis in breast carcinoma. Breast compression and projective images acquisition alter the quantitative assessment of enhancement parameters.
Ähnliche Arbeiten
Index for rating diagnostic tests
1950 · 11.331 Zit.
3D Slicer as an image computing platform for the Quantitative Imaging Network
2012 · 8.643 Zit.
Computational Radiomics System to Decode the Radiographic Phenotype
2017 · 6.340 Zit.
MR diffusion tensor spectroscopy and imaging
1994 · 6.015 Zit.
Tumor Angiogenesis and Metastasis — Correlation in Invasive Breast Carcinoma
1991 · 5.672 Zit.
Autoren
Institutionen
- Immunologie, Immunopathologie et Chimie Thérapeutique(FR)
- Institute of Astronomy and Astrophysics, Academia Sinica(TW)
- Institut de Radioastronomie Millimétrique(FR)
- Institut de Biologie Moléculaire et Cellulaire(FR)
- Ecosystèmes, Biodiversité, Evolution(FR)
- Institut Gustave Roussy(FR)
- Institut thématique Immunologie, inflammation, infectiologie et microbiologie(FR)
- Hôpital Nord(FR)