Dies ist eine Übersichtsseite mit Metadaten zu dieser wissenschaftlichen Arbeit. Der vollständige Artikel ist beim Verlag verfügbar.
Effectiveness evaluation of computer-aided diagnosis system for the diagnosis of thyroid nodules on ultrasound
62
Zitationen
5
Autoren
2019
Jahr
Abstract
BACKGROUND: More and more automated efficient ultrasound image analysis techniques, such as ultrasound-based computer-aided diagnosis system (CAD), were developed to obtain accurate, reproducible, and more objective diagnosis results for thyroid nodules. So far, whether the diagnostic performance of existing CAD systems can reach the diagnostic level of experienced radiologists is still controversial. The aim of the meta-analysis was to evaluate the accuracy of CAD for thyroid nodules' diagnosis by reviewing current literatures and summarizing the research status. METHODS: A detailed literature search on PubMed, Embase, and Cochrane Libraries for articles published until December 2018 was carried out. The diagnostic performances of CAD systems vs radiologist were evaluated by meta-analysis. We determined the sensitivity and the specificity across studies, calculated positive and negative likelihood ratios and constructed summary receiver-operating characteristic (SROC) curves. Meta-analysis of studies was performed using a mixed-effect, hierarchical logistic regression model. RESULTS: Five studies with 536 patients and 723 thyroid nodules were included in this meta-analysis. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio (DOR) for CAD system were 0.87 (95% confidence interval [CI], 0.73-0.94), 0.79 (95% CI 0.63-0.89), 4.1 (95% CI 2.5-6.9), 0.17 (95% CI 0.09-0.32), and 25 (95% CI 15-42), respectively. The SROC curve indicated that the area under the curve was 0.90 (95% CI 0.87-0.92). The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and DOR for experienced radiologists were 0.82 (95% CI 0.69-0.91), 0.83 (95% CI 0.76-0.89), 4.9 (95% CI 3.4-7.0), 0.22 (95% CI 0.12-0.38), and 23 (95% CI 11-46), respectively. The SROC curve indicated that the area under the curve was 0.96 (95% CI 0.94-0.97). CONCLUSION: The sensitivity of the CAD system in the diagnosis of thyroid nodules was similar to that of experienced radiologists. However, the CAD system had lower specificity and DOR than experienced radiologists. The CAD system may play the potential role as a decision-making assistant alongside radiologists in the thyroid nodules' diagnosis. Future technical improvements would be helpful to increase the accuracy as well as diagnostic efficiency.
Ähnliche Arbeiten
2015 American Thyroid Association Management Guidelines for Adult Patients with Thyroid Nodules and Differentiated Thyroid Cancer: The American Thyroid Association Guidelines Task Force on Thyroid Nodules and Differentiated Thyroid Cancer
2015 · 16.295 Zit.
Revised American Thyroid Association Management Guidelines for Patients with Thyroid Nodules and Differentiated Thyroid Cancer
2009 · 6.737 Zit.
Serum TSH, T<sub>4</sub>, and Thyroid Antibodies in the United States Population (1988 to 1994): National Health and Nutrition Examination Survey (NHANES III)
2002 · 3.859 Zit.
Increasing Incidence of Thyroid Cancer in the United States, 1973-2002
2006 · 3.360 Zit.
Integrated Genomic Characterization of Papillary Thyroid Carcinoma
2014 · 3.049 Zit.