OpenAlex · Aktualisierung stündlich · Letzte Aktualisierung: 29.04.2026, 09:11

Dies ist eine Übersichtsseite mit Metadaten zu dieser wissenschaftlichen Arbeit. Der vollständige Artikel ist beim Verlag verfügbar.

The application of fracture recovery techniques based on 3D printing and three-dimensional data correction scheme in fractures of the proximal femur

2018·0 Zitationen·Chin J Anat Clin
Volltext beim Verlag öffnen

0

Zitationen

4

Autoren

2018

Jahr

Abstract

Objective To explore a 3D printing model of fracture restoration which can be used in preoperative planning and design for proximal femur fractures. To study the feasibility of clinical application of three-dimensional data correction scheme. Methods An analysis of the 47 patients with proximal femur fracture treated from October 2015 to September 2017 in Department of Orthopaedics of Liyang People's Hospital was conducted. Bilateral femur CT scan was performed in all the cases to obtain DICOM data. Using Mimics 15.0 software, cross were created at 5 cm, 10 cm and 15 cm above the knee joint at the bilateral distal femur and marked as DF5, DF10 and DF15. The long and short axles on the left and right sides were measured and compared. If the femur was tilted, the correction data would be used. All the data were collected of the long and short axles on the 3 cross-sections (DF5, DF10 and DF15) of the left and right sides of the distal femur. After the STL files for 3D models were generated by using Mimics 15.0 software, a real-sized 3D model of the proximal femur fracture and a mirror model of the contralateral femur were printed. The preoperative manoeuvre was performed on the mirror 3D printed model. The real operation used the implants preoperatively designed, and compared radiographically with those designed in the preoperative manoeuvre. Results There were significant differences between the short axis of the left and right femoral condyle 5 cm from the intercondylar keel [(28.54±3.51) mm vs. (28.20±3.41) mm, t=3.404, P 0.05). All the 47 patients received surgical operation. The postoperative X-ray review showed fine agreement between actual surgery and preoperative design in terms of screw length and accuracy. The deviations were in an allowable range, leading to satisfactory internal fixation. Conclusions Symmetry of the bilateral femur can be judged by the comparison of long axis and short axis of three equidistant transverse sections methods. If the deviation is less than 5%, the preoperative implants would be directly used. It is satisfactory for postoperative radiography validation. Three-dimensional data correction scheme expands the Comparison of long axis and short axis of three equidistant transverse sections data selection range, which can effectively avoid the data failure because of limb tilt . Key words: Femoral fracture; Fracture fixation, internal; 3D printing technology; Long bone; Dihedral angle

Ähnliche Arbeiten

Autoren

Themen

Hip and Femur FracturesArtificial Intelligence in Healthcare and EducationBone fractures and treatments
Volltext beim Verlag öffnen