Dies ist eine Übersichtsseite mit Metadaten zu dieser wissenschaftlichen Arbeit. Der vollständige Artikel ist beim Verlag verfügbar.
Quality improvement time-saving intervention to increase use of a clinical decision support tool to reduce low-value diagnostic imaging in a safety net health system
12
Zitationen
7
Autoren
2021
Jahr
Abstract
IMPORTANCE: Electronic health record (EHR) clinical decision support (CDS) tools can provide evidence-based feedback at the point of care to reduce low-value imaging. Success of these tools has been limited partly due to lack of engagement by busy clinicians. OBJECTIVE: Measure the impact of a time-saving quality improvement intervention to increase engagement with a CDS tool for low back pain imaging ordering. DESIGN, SETTING AND PARTICIPANTS: We conducted a quasi-experimental difference-in-differences analysis at (BLINDED), examining back pain imaging orders from 29 May 2015 to 07 January 2016. The intervention site was (BLINDED) Emergency Medicine/Urgent Care Center (n=5736) and control sites included all other (BLINDED) hospitals and clinics (n=1621). In May 2015, the Department of Health Services installed a CDS tool that triggered a survey when clinicians ordered an imaging test, generating an 'appropriateness score' based on the American College of Radiology guidelines. Clinicians often bypassed the tool, resulting in 'unscored' tests. INTERVENTION: To increase clinician engagement with the tool and decrease the rate of unscored imaging tests, a new policy was implemented at the intervention site on 15 August 2015. If clinicians completed the CDS survey and scored an appropriateness score >3, they could forego a previously mandatory telephone call for pre-imaging utilisation review with the radiology department. MAIN OUTCOMES AND MEASURES: We used EHR data to measure pre-post-intervention differences in: (1) percentage of unscored tests and (2) percentage of tests with high appropriateness scores (>7). RESULTS: Percentage of unscored tests decreased from 69.4% to 10.4% at the intervention site and from 50.6% to 34.8% at the control sites (between-group difference: -23.3%, p<0.001). Percentage of high scoring tests increased from 26.5% to 75.0% at the intervention site and from 17.2% to 22.7% at the control sites (between-group difference: 19%, p<0.001). CONCLUSION: Workflow time-saving interventions may increase physician engagement with CDS tools and have potential to improve practice patterns.
Ähnliche Arbeiten
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
2011 · 33.919 Zit.
To Err Is Human
2000 · 14.089 Zit.
Strengthening the reporting of observational studies in epidemiology (STROBE) statement: guidelines for reporting observational studies
2007 · 9.814 Zit.
KDIGO 2024 Clinical Practice Guideline for the Evaluation and Management of Chronic Kidney Disease
2024 · 7.129 Zit.
Dissecting racial bias in an algorithm used to manage the health of populations
2019 · 5.859 Zit.