Dies ist eine Übersichtsseite mit Metadaten zu dieser wissenschaftlichen Arbeit. Der vollständige Artikel ist beim Verlag verfügbar.
Development and web deployment of an automated neuroradiology MRI protocoling tool with natural language processing
16
Zitationen
9
Autoren
2021
Jahr
Abstract
BACKGROUND: A systematic approach to MRI protocol assignment is essential for the efficient delivery of safe patient care. Advances in natural language processing (NLP) allow for the development of accurate automated protocol assignment. We aim to develop, evaluate, and deploy an NLP model that automates protocol assignment, given the clinician indication text. METHODS: We collected 7139 spine MRI protocols (routine or contrast) and 990 head MRI protocols (routine brain, contrast brain, or other) from a single institution. Protocols were split into training (n = 4997 for spine MRI; n = 839 for head MRI), validation (n = 1071 for spine MRI, fivefold cross-validation used for head MRI), and test (n = 1071 for spine MRI; n = 151 for head MRI) sets. fastText and XGBoost were used to develop 2 NLP models to classify spine and head MRI protocols, respectively. A Flask-based web app was developed to be deployed via Heroku. RESULTS: The spine MRI model had an accuracy of 83.38% and a receiver operator characteristic area under the curve (ROC-AUC) of 0.8873. The head MRI model had an accuracy of 85.43% with a routine brain protocol ROC-AUC of 0.9463 and contrast brain protocol ROC-AUC of 0.9284. Cancer, infectious, and inflammatory related keywords were associated with contrast administration. Structural anatomic abnormalities and stroke/altered mental status were indicative of routine spine and brain MRI, respectively. Error analysis revealed increasing the sample size may improve performance for head MRI protocols. A web version of the model is provided for demonstration and deployment. CONCLUSION: We developed and web-deployed two NLP models that accurately predict spine and head MRI protocol assignment, which could improve radiology workflow efficiency.
Ähnliche Arbeiten
Refinement and reassessment of the SERVQUAL scale.
1991 · 3.967 Zit.
Radiobiology for the Radiologist.
1974 · 3.502 Zit.
ACR Thyroid Imaging, Reporting and Data System (TI-RADS): White Paper of the ACR TI-RADS Committee
2017 · 2.442 Zit.
Accuracy of Physician Self-assessment Compared With Observed Measures of Competence
2006 · 2.329 Zit.
Technology as an Occasion for Structuring: Evidence from Observations of CT Scanners and the Social Order of Radiology Departments
1986 · 2.254 Zit.