Marker-3D Measurement Versus Traditional Radiograph Measurement in the Treatment of Tibiofibular Fracture Using Taylor Spatial Frame
0
Zitationen
8
Autoren
2021
Jahr
Abstract
Abstract Background : The Taylor Spatial Frame (TSF) has been widely used for tibiofibular fractures. However, traditional radiograph measurement method is complicated and the reduction accuracy is not high enough for correcting residual deformities. We proposed the marker-3D measurement method to solve these problems. This study aimed to compare the reduction accuracy of the traditional radiograph measurement method and the marker-3D measurement method in tibiofibular fracture treated with TSF. Methods : From January 2016 to June 2019, A retrospective analysis was performed based on the patients with tibiofibular fracture treated with TSF in our department. 41 patients were qualified for this study, including 21 patients in the marker-3D measurement group (experimental group) and 20 patients in the traditional radiograph measurement group (control group). In the experimental group, CT scan was performed for 3D reconstruction with 6 markers installed on the TSF, to determine the adjusting plan. In the control group, the anteroposterior (AP) and lateral radiographs were performed for the deformity parameters. X-rays were taken to measure the residual deformities after correction. Results : All patients reached functional reduction. The residual displacement deformity (RDD) in AP radiograph was 0.5 (0, 1.72) mm in experimental group and 1.74 (0.43, 3.67) mm in control group. The residual angle deformity (RAD) in AP radiograph was 0 (0, 1.25) ° in experimental group and 1.25 (0.62, 1.95) °in control group. As to the Lateral radiograph, the RDD was 0 (0, 1.22) mm in experimental group and 2.02 (0, 3.74) mm in control group. The RAD was 0 (0, 0) ° in experimental group and 1.42 (0, 1.93) ° in control group. Significant differences in all above comparisons were found between the groups (AP radiograph RDD: P = 0.024, RAD: P = 0.020; Lateral radiograph RDD: P = 0.016, RAD: P = 0.004). Conclusions : Both groups achieved satisfactory fracture reduction. However, the residual deformities in the experimental group were significantly smaller. This study proved that the marker-3D measurement method could further improve the reduction accuracy.
Ähnliche Arbeiten
An estimate of the worldwide prevalence and disability associated with osteoporotic fractures
2006 · 4.612 Zit.
ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion—Part II: shoulder, elbow, wrist and hand
2004 · 4.428 Zit.
Meta-analysis of how well measures of bone mineral density predict occurrence of osteoporotic fractures
1996 · 3.693 Zit.
Burden of major musculoskeletal conditions.
2003 · 3.529 Zit.
Prevention of infection in the treatment of one thousand and twenty-five open fractures of long bones
1976 · 3.244 Zit.
Autoren
Institutionen
- Anhui Medical University(CN)
- Tianjin Hospital(CN)
- Fourth Affiliated Hospital of Anhui Medical University(CN)
- Pudong New Area People's Hospital(CN)
- Tianjin Medical University(CN)
- Xinjiang Medical University(CN)
- First Affiliated Hospital of Xinjiang Medical University(CN)
- Anhui Provincial Hospital(CN)
- Tianjin University(CN)