Dies ist eine Übersichtsseite mit Metadaten zu dieser wissenschaftlichen Arbeit. Der vollständige Artikel ist beim Verlag verfügbar.
Radiation Oncologists’ Perceptions of Adopting an Artificial Intelligence–Assisted Contouring Technology: Model Development and Questionnaire Study
52
Zitationen
10
Autoren
2021
Jahr
Abstract
BACKGROUND: An artificial intelligence (AI)-assisted contouring system benefits radiation oncologists by saving time and improving treatment accuracy. Yet, there is much hope and fear surrounding such technologies, and this fear can manifest as resistance from health care professionals, which can lead to the failure of AI projects. OBJECTIVE: The objective of this study was to develop and test a model for investigating the factors that drive radiation oncologists' acceptance of AI contouring technology in a Chinese context. METHODS: A model of AI-assisted contouring technology acceptance was developed based on the Unified Theory of Acceptance and Use of Technology (UTAUT) model by adding the variables of perceived risk and resistance that were proposed in this study. The model included 8 constructs with 29 questionnaire items. A total of 307 respondents completed the questionnaires. Structural equation modeling was conducted to evaluate the model's path effects, significance, and fitness. RESULTS: The overall fitness indices for the model were evaluated and showed that the model was a good fit to the data. Behavioral intention was significantly affected by performance expectancy (β=.155; P=.01), social influence (β=.365; P<.001), and facilitating conditions (β=.459; P<.001). Effort expectancy (β=.055; P=.45), perceived risk (β=-.048; P=.35), and resistance bias (β=-.020; P=.63) did not significantly affect behavioral intention. CONCLUSIONS: The physicians' overall perceptions of an AI-assisted technology for radiation contouring were high. Technology resistance among Chinese radiation oncologists was low and not related to behavioral intention. Not all of the factors in the Venkatesh UTAUT model applied to AI technology adoption among physicians in a Chinese context.
Ähnliche Arbeiten
Radiative Transfer
1950 · 8.660 Zit.
Practical cone-beam algorithm
1984 · 6.207 Zit.
Toxicity criteria of the Radiation Therapy Oncology Group (RTOG) and the European organization for research and treatment of cancer (EORTC)
1995 · 4.811 Zit.
Tolerance of normal tissue to therapeutic irradiation
1991 · 4.459 Zit.
Clonogenic assay of cells in vitro
2006 · 4.126 Zit.