Dies ist eine Übersichtsseite mit Metadaten zu dieser wissenschaftlichen Arbeit. Der vollständige Artikel ist beim Verlag verfügbar.
Out‐of‐distribution detection with in‐distribution voting using the medical example of chest x‐ray classification
10
Zitationen
5
Autoren
2023
Jahr
Abstract
BACKGROUND: Deep learning models are being applied to more and more use cases with astonishing success stories, but how do they perform in the real world? Models are typically tested on specific cleaned data sets, but when deployed in the real world, the model will encounter unexpected, out-of-distribution (OOD) data. PURPOSE: To investigate the impact of OOD radiographs on existing chest x-ray classification models and to increase their robustness against OOD data. METHODS: The study employed the commonly used chest x-ray classification model, CheXnet, trained on the chest x-ray 14 data set, and tested its robustness against OOD data using three public radiography data sets: IRMA, Bone Age, and MURA, and the ImageNet data set. To detect OOD data for multi-label classification, we proposed in-distribution voting (IDV). The OOD detection performance is measured across data sets using the area under the receiver operating characteristic curve (AUC) analysis and compared with Mahalanobis-based OOD detection, MaxLogit, MaxEnergy, self-supervised OOD detection (SS OOD), and CutMix. RESULTS: Without additional OOD detection, the chest x-ray classifier failed to discard any OOD images, with an AUC of 0.5. The proposed IDV approach trained on ID (chest x-ray 14) and OOD data (IRMA and ImageNet) achieved, on average, 0.999 OOD AUC across the three data sets, surpassing all other OOD detection methods. Mahalanobis-based OOD detection achieved an average OOD detection AUC of 0.982. IDV trained solely with a few thousand ImageNet images had an AUC 0.913, which was considerably higher than MaxLogit (0.726), MaxEnergy (0.724), SS OOD (0.476), and CutMix (0.376). CONCLUSIONS: The performance of all tested OOD detection methods did not translate well to radiography data sets, except Mahalanobis-based OOD detection and the proposed IDV method. Consequently, training solely on ID data led to incorrect classification of OOD images as ID, resulting in increased false positive rates. IDV substantially improved the model's ID classification performance, even when trained with data that will not occur in the intended use case or test set (ImageNet), without additional inference overhead or performance decrease in the target classification. The corresponding code is available at https://gitlab.lrz.de/IP/a-knee-cannot-have-lung-disease.
Ähnliche Arbeiten
La certeza de lo impredecible: Cultura Educación y Sociedad en tiempos de COVID19
2020 · 19.307 Zit.
A Multi-Modal Distributed Real-Time IoT System for Urban Traffic Control (Invited Paper)
2024 · 14.302 Zit.
UNet++: A Nested U-Net Architecture for Medical Image Segmentation
2018 · 8.794 Zit.
Review of deep learning: concepts, CNN architectures, challenges, applications, future directions
2021 · 7.406 Zit.
scikit-image: image processing in Python
2014 · 6.840 Zit.