Dies ist eine Übersichtsseite mit Metadaten zu dieser wissenschaftlichen Arbeit. Der vollständige Artikel ist beim Verlag verfügbar.
AI-Enabled ECG Analysis Improves Diagnostic Accuracy and Reduces False STEMI Activations
12
Zitationen
19
Autoren
2025
Jahr
Abstract
BACKGROUND: Timely reperfusion is critical in reducing mortality in ST-segment elevation myocardial infarction (STEMI). Although electrocardiography-guided cardiac catheterization laboratory (CCL) activation on the basis of first medical contact recognition improves system-level response, diagnostic uncertainty, particularly in atypical presentations, contributes to false positive activations (FPAs) and reperfusion delays. OBJECTIVES: The aim of this study was to evaluate the diagnostic performance and operational impact of artificial intelligence (AI)-based electrocardiographic (ECG) analysis in real-world STEMI triage across a multicenter U.S. registry. METHODS: A total of 1,032 patients with suspected STEMI who triggered emergent CCL activation at 3 geographically diverse percutaneous coronary intervention centers (January 2020 to May 2024) were retrospectively analyzed. Index electrocardiograms underwent standard triage and blinded retrospective AI ECG analysis (Queen of Hearts, PMcardio) trained to detect acute coronary occlusion and benign mimics. The reference standard was an angiographically confirmed culprit lesion with positive enzymes. Diagnostic accuracy, subgroup analyses, and FPA reclassification were compared. RESULTS: Of 1,032 emergent CCL activations, 601 (58.2%) had confirmed STEMI. The AI ECG model outperformed standard triage, demonstrating higher index ECG sensitivity (553 of 601 [92.0%; 95% CI: 89.7%-94.1%] vs 427 of 601 [71.0%; 95% CI: 67.4%-74.6%]), reducing FPA rates (34 of 431 [7.9%; 95% CI: 6.4%-9.6%] vs 180 of 431 [41.8%; 95% CI: 38.9%-44.7%]), and improving specificity (431 of 531 [81.0%; 95% CI: 77.2%-84.5%] vs 154 of 531 [29.0%; 95% CI: 24.8%-33.4%]) (P < 0.001 for all). The AI ECG model's area under the receiver-operating characteristic curve was 0.94 (95% CI: 0.92-0.95), maintaining consistent performance across clinically challenging subgroups (eg, atrial fibrillation, bundle branch block, STEMI equivalents). The AI ECG model reclassified 277 of 306 (91%) biomarker-negative FPAs correctly. CONCLUSIONS: AI-based ECG analysis significantly improved STEMI detection, reduced FPAs, and enhanced the recognition of nonconventional presentations. This supports integration of AI-based ECG analysis into acute chest pain pathways.
Ähnliche Arbeiten
A Real-Time QRS Detection Algorithm
1985 · 7.679 Zit.
An Overview of Heart Rate Variability Metrics and Norms
2017 · 6.628 Zit.
Power Spectrum Analysis of Heart Rate Fluctuation: A Quantitative Probe of Beat-to-Beat Cardiovascular Control
1981 · 5.073 Zit.
The impact of the MIT-BIH Arrhythmia Database
2001 · 4.573 Zit.
Decreased heart rate variability and its association with increased mortality after acute myocardial infarction
1987 · 4.001 Zit.
Autoren
Institutionen
- Onze Lieve Vrouwziekenhuis Hospital(BE)
- University of California, Davis(US)
- Beth Israel Deaconess Medical Center(US)
- Memorial Hermann(US)
- Texas Medical Center(US)
- Sapienza University of Rome(IT)
- Baim Institute for Clinical Research(US)
- National Institute of Cardiovascular Diseases(SK)
- University of Minnesota(US)
- Hennepin County Medical Center(US)
- Carolinas Medical Center(US)
- Abbott Northwestern Hospital(US)
- Flanders Environment Agency(BE)
- Christ Hospital(US)